Controller ratings (continued), Input current ratings, Class 8839 econoflex™ ac drives – Schneider Electric ALTIVAR 58 TRX User Manual
Page 195: Ratings
Class 8839 Econoflex™ AC Drives
Ratings
195
09/2003
©
2000–2003 Schneider Electric All Rights Reserved
CONTROLLER RATINGS (CONTINUED)
INPUT CURRENT RATINGS
Class 8839 ATV58 Econoflex Drive Controller Ratings 208 Vac
Drive Controller
Catalog Number
◆
Motor Power
▲
208 Vac 60 Hz (HP)
Maximum Continuous
Output Current (A)
■
Max. Transient (60 s)
Output Current (A)
Power Converter
Part Number
58EC•2V_
1
4.6 5.1
FLEX58U29M2
58ED•2V_
2
7.5 8.3
FLEX58U29M2
58EE•2V_
3
10.6 11.7
FLEX58U41M2
58EF•2V_
5
16.7 18.4
FLEX58U72M2
58EG•2V_
7.5
24.2 26.6
FLEX58U90M2
58EH•2V_
10
30.8 33.9
FLEX58D12M2
58EJ•2V_
15
46.2 50.8
FLEX58D16M2
58EK•2V_
20
59.4 65.3
FLEX58D16M2
58EL•2V_
25
74.8 82.3
FLEX58D23M2
58EM•2V_
30
88
96.8 FLEX58D28M2
58EN•2V_
40
114
125.4 FLEX58D33M2
58EP•2V_
50
143
157.3 FLEX58D46M2
◆
The • may be A or G; A denotes a Type 12K enclosure, G denotes a Type 1 enclosure. The underscore (_) indicates that the catalog number
continues. See page 186 for detailed description of catalog numbers.
▲
Power shown is for a carrier switching frequency of 8 kHz. For a switching frequency between 12 and 1 6kHz, select the next largest size drive
controller. If the duty cycle does not exceed 60% (36 s maximum for a 60 s cycle), this is not necessary.
■
Continuous output current based on NEC table 430-150. The Econoflex controller nameplate rating is per the NEC table, not the current value listed
in the keypad lookup table.
Input Line Currents for Selection of Branch Circuit Feeder for Class 8839 Econoflex 460 Vac
▲
Drive Controller
Catalog Number
▼
Motor Power
460 Vac 60 Hz
(HP)
5 kAIC (0.141 mH)
10 kAIC (0.070 mH)
(A)
22 kAIC
(0.032 mH)
(A)
Factory-mounted Line Reactor
■
Mod A09
5 kAIC (0.141 mH)
10 kAIC (0.070 mH)
(A)
22 kAIC
(0.032 mH)
(A)
58EC•4V_
1
2.8
3.2
1.8
2
58ED•4V_
2
4.8
5.2
3.5
3.8
58EE•4V_
3
6.5
7.6
4.9
5.7
58EF•4V_
5
10.7
12.6
7.9
9.3
58EG•4V_
7.5
14.3
16.9
11.5
13.2
58EH•4V_
10
18.2
22
12.9
15.6
58EJ•4V_
15
25.3
30.3
22.9
22.9
58EK•4V_
20
32
38.4
25.2
30
58EL•4V_
25
32.7
34.1
32.7
34.1
58EM•4V_
30
38.1
39.8
38.1
39.8
58EN•4V_
40
49.3
51.6
49.3
51.6
58EP•4V_
50
61.8
65.4
61.8
65.4
58EQ•4V_
60
75.2
◆
77.7
75.2
◆
77.7
58ER•4V_
75
96.3
◆
100.8
96.3
◆
100.8
58ES•4V_
100
122.6
◆
129.3
122.6
◆
129.3
▲
Select conductor based on NEC.
▼
The • may be A or G; A denotes a Type 12K enclosure; G denotes a Type 1 enclosure. The underscore (_) indicates that the catalog number
continues. See page 186 for detailed description of catalog numbers.
■
Factory modification A09 is optional for 1 to 20 HP controllers and included in 25 to 100 HP controllers.
◆
10 kAIC.