Schumacher 00-99-000886 User Manual
Page 8
•
5
•
DANGER – Never alter AC cord or plug provided – if it does not fit the
outlet, have proper outlet installed by a qualified electrician. Improper
connection can result in a risk of an electric shock or fire.
Recommended minimum AWG size for extension cords for battery
8.2
chargers
25
50
100
150
(7.6)
(15.2)
(30.5)
(45.6)
0
2
18
18
18
16
2
3
18
18
16
14
3
4
18
18
16
14
4
5
18
18
14
12
5
6
18
16
14
12
6
8
18
16
12
10
8
10
18
14
12
10
10
12
16
14
10
8
12
14
16
12
10
8
14
16
16
12
10
8
16
18
14
12
8
8
18
20
14
12
8
6
a
If the input rating of a charger is given in watts rather than in
amperes, the corresponding ampere rating is to be determined
by dividing the wattage rating by the voltage rating ± for
example:
1250 watts/125 volts = 10 amperes
Length of cord, feet (m)
AWG size of cord
AC input rating,
amperes
a
But less
than
At least
Grounding Methods
8.3
This charger must be properly grounded. Make sure the AC outlet you are
plugging it into is properly grounded per local codes and regulations. If it
is not, have one installed by a qualified service person. Do not remove or
bypass the grounding pin on the plug or receptacle.
ASSEMBLy INSTRUCTIONS
9.