Using the Battery Voltage Tester
Overview

This battery charger has a built-in voltmeter to test your battery’s state of

charge. The charger does not have a built in load tester. As such, a recently

charged battery could have a temporarily high voltage due to what is known as

“surface charge.” The voltage of such a battery will gradually drop during the

period immediately after the charging system is disengaged. Consequently, the

tester could display inconsistent values for such a battery. For a more accurate

reading, the surface charge should be removed by temporarily creating a load

on the battery, such as by turning on lights or other accessories for a couple

of minutes before you read the display. Read it a couple of minutes after you

have shut the headlights off.
Testing Sequence: There are four basic steps required to test the battery

state of charge:

With the charger unplugged from the AC outlet, connect the charger to the

1.

battery following the instructions given in sections 6 and 7.
Plug the charger AC power cord into the AC outlet, following the

2.

instructions given in section 8.
If necessary, press the BATTERY TYPE button until the correct type is

3.

indicated.
Read the voltage on the digital display. Compare the readings to the chart

4.

below.

NOTE: After 15 minutes, the charger will automatically switch from tester to

charger.

6 Volt Battery

Voltage Reading

12 Volt Battery

Voltage Reading

Battery Condition

6.4 or More

12.8 or More

Charged

6.1 to 6.3

12.2 to 12.7

Needs Charging

Less than 6.1

Less than 12.2

Discharged

Tester and Charger: When first turned on, the unit operates only as a tester,

not as a charger. To continue to use it only as a tester, avoid pressing the

CHARGE RATE button. Selecting a charge rate activates the battery charger

and deactivates the tester. Pressing the CHARGE RATE button when the

ENGINE START LED is lit (except during the 180 second cool down) will shut

off the charger and activate the tester.
Power-Up Idle Time Limit: If no button is pressed within 15 minutes after the

battery charger is first powered up, the charger will automatically switch from

tester to charger if a battery is connected. In that case, the charger will be set

to the start up default settings.
Testing After Charging: After the unit has been changed from tester to

charger (by selecting a charge rate), it remains a charger. To change the

battery charger back to a tester, press the CHARGE RATE switch until all

charge rate LED’s are off.
Tester Status LEDs: When the unit is operating as a battery tester, the status

LEDs light under the following conditions:

The CHARGED LED

will light if a charged battery is tested.

The CHARGING LED

does not light in the battery test mode.

The

CONNECTED LED lights when a properly connected battery is

detected.