PROBLEM: EXCESSIVE CHAIN NOISE

MISALIGNED SPROCKETS

Check sprockets for worn edges of teeth. Use a straight edge to

verify the alignment of the sprockets.

WORN SPROCKET AND OR CHAIN

Inspect sprockets and chains. Replace if excessively worn.

CAUSE

SOLUTION

PROBLEM: MOTOR RUNS, BUT REEL AND AUGERS DO NOT TURN

CAUSE

SOLUTION

SHEAR BOLT ON PTO DRIVELINE HAS SHEARED

Replace with Same Grade and size shear bolt. Do not us any

bolt other than a Gr 5 see PTO driveline setup for more information.

If problem persists, call Kuhn Knight Inc. Service Dept.

BELTS ARE SLIPPING

Adjust or replace belts as outlined in “INSPECTION AND

ADJUSTMENT” section. If problem persists, call Kuhn Knight Inc.

Service Dept.

BROKEN CHAIN

Make sure that mixer is not overloaded. Replace broken chain.

A spliced chain will not be as strong as a new chain and may

break in another place. Be sure to inspect bearings, bearing

mounts, and shafts for any damage caused by excessive

pressure

PROBLEM: SEAL LEAKING ON UPPER AUGER

CAUSE

SOLUTION

BOLTS MAY HAVE WORKED LOOSE ON SEAL RETAINER

Tighten or replace bolts

SEAL IS DAMAGED

Replace Seal

PROBLEM: SEAL LEAKING ON INPUT SHAFT

OIL BATH IS OVERFILLED

The oil level in the sealed drive compartment should be main-

tained at the “oil level” plug on the drive compartment housing.

This allows the oil to be thrown onto all the other chains inside

the drive compartment.

SEAL IS DAMAGED

Replace Seal

CAUSE

SOLUTION

PROBLEM: FEED IS SEPARATING AS IT DISCHARGES FROM THE MIXER DOOR

DOOR IS OPEN LESS THAN HALF WAY

Hay mixed in the load will separate from the grain if the dis-

charge door is not open at least half way. Additional flow control

plates may be required.

CAUSE

SOLUTION

TROUBLE SHOOTING