Using the KODAK EKTACOLOR Processing Cartridge 111 With Digital Minilabs, CP-48S/CP-49E

CIS-229E

8

USING KODAK CONTROL STRIPS /

PROCESS RA-4 / EXTENDED LENGTH IN

THE FUJI FRONTIER DIGITAL MINILAB

KODAK Control Strips, Process RA-4 / Extended
Length, CAT No.130 4690, are designed for use in all
Control Strip Holders for FUJI FRONTIER and NORITSU
3501F and 3701F Digital Minilabs. No shim is required
when using these extended length strips. If you have
installed a shim in your control strip magazine for using
the standard length KODAK Control Strips, Process
RA-4,, please remove it before using the strips. Use
these strips for the most accurate process monitoring
when you process KODAK EKTACOLOR ROYAL and
KODAK EKTACOLOR EDGE Papers.

For calculating the aims for your control strip code, read
the Status A Red, Green, and Blue densities of the
reference strip, and then apply the correction factors.
For the HD-LD parameter, subtract the corrected LD
from the corrected HD density readings. You will find
three sets of correction factors on the reference envelop
for you to use in calculating the aims. Make sure you
select the correct PC 111 correction factors for the
specific FUJI FRONTIER or NORITSU “F” Model Digital
Minilabs you are using:

For FRONTIER Models 330, 350. 355, 370, 375, and
390, using Process CP-48S, use the correction
factors labeled: EKTACOLOR PC11148S

For FRONTIER Model 340, and NORITSU models
3701/02/03/04F using Process CP-49E, use the
correction factors labeled: EKTACOLOR PC11149E

For the FRONTIER Models 550, 570, or NORITSU
Model 3501/02F and 3705F, using Process CP-49E,
use the correction factors labeled:
EKTACOLOR PC111495