Installation – Lincoln Electric MAGNUM IM438-B User Manual

Page 8

Advertising
background image

A-1

INSTALLATION

MAGNUM COOLER 10-I & 20-I

A-1

TECHNICAL SPECIFICATIONS – MAGNUM COOLERS 10-I AND 20-I

Model

Cooler 10-I

Cooler 20-I

Product No.

K873-1

K879-1

Input

220V 50/60 Hz 1 Phase

220V 50/60 Hz 1 Phase

Current Draw at Input

.75 Amps

1.25 Amps

Rated Current Draw

1.0 Amps

1.6 Amps

Operating Pressure

45 psi (310 kPa) (3.0 bar)

60 psi (410 kPa) (4.0 bar)

Shutdown Pressure

60-65 psi (414-446 kPa)

(No delay after flow is

(4.0-4.4 bar)

stopped)

Flow Range

0.1 to 0.8 gal/min (0.4 to 3.0 liters/min)

Typical

MIG

with Magnum 15’ (4.5m) gun 0.55-0.60 gal/min (2.1-2.3 liters/min)

Operating
Flow

TIG

with Magnum 12.5’ (3.8m) torch 0.25-0.30 gal/min (1.0-1.2 liters/min)

Open Flow

0.8 (3.0 liters/min)

Reservoir Size

2.0 ga. (8.0 liters)

Coolant Requirement

For Use Above Freezing: Tap, distilled, de-ionized, mineral water or well water.

For Use Below Freezing: 50% water and 50% automotive antifreeze mixture
such as Prestone, Peak or Zerex or 50% water and 50% pure ethylene glycol
mixture or any water alcohol mixture.

DO NOT USE: Prepackaged welding industry coolants. These coolants may
contain oil-based substances which attack the plastic components in the pump
of the Magnum Cooler and severely reduce pump life.

Weight

Shipping

30 lbs. (13.6 kg)

34 lbs. (15.4 kg)

Reservoir

43 lbs. (19.5 kg)

47 lbs. (21.3 kg)

Full

Dimensions

L

9.0 in. (229mm)

9.0 in. (229mm)

W

9.0 in. (229mm)

9.0 in. (229mm)

H Top Face

26.5 in. (673mm)

32.00 in. (815mm)

H Top

28.75 in. (730mm)

34.25 in. (870mm)

Handle

Undercarriage Use

K874

K840-1*, K841-1*, K842-1*,
K874

* Not available at the time of printing.

MAR97