11.0 Error Codes

18

© Baxi Heating UK Ltd 2010

Error code: Display

Description

Lockout/Reset action

Eng

Sup

10: Outside sensor

Fault outside temp sensor1

AR

AR

20: Boiler flow sensor

Fault boiler flow temp sensor

AR

AR

40: Boiler return sensor

Fault return temp sensor boiler

AR

AR

50: DHW tank sensor

Fault DHW1 sensor

AR

AR

60: Room sensor 1

Fault room temp sensor HC1

AR

AR

65: Room sensor 2

Fault room temp sensor HC2

AR

AR

83: BSB short-circuit

Boiler system bus short-circuit

AR

AR

84: BSB address collision

More then 1 room units are assigned to the same HC

Assign one of them to HC2 or assign QAA7x not as room unit

AR

AR

85: Radio communication

Communication to radio device interrupted

AR•

AR•

91: Data loss in EEPROM

Failure in Class B-SW: Irreparable data loss in EEPROM

NRP

NRP

92: Device electronics error

RAM failure, HBC processor register failure, blocking chain

undefined (toggling), safety chain discrepancy.

Reset: Press Service Reset within 20 seconds after Power up

NRP

NRP

95: Time of day invalid

The real time clock unit detected corrupted time of day.

96: Minor SW failure

Failure in Class B-SW: Stack overflow or program sequence failure

AR

AR

97: SW or HW failure

Failure in EGC-SW which causes non-volatile lock.

NRP

NRP

127: Legionella temperature

Legionella temperature not achieved within 48 hours

AR+

AR+

157: Boiler Flow Overheat stat

Boiler flow overheat thermostat / safety chain open

UR

UR

158: Condensate

Condensate switch of safety chain opened

UR

UR

164: Flow

Low flow or faulty flow switch

AR

AR

257: Pack sensor

Fault pack temp sensor

258: Pack over- temp

Internal ambient temperature to high

AR

AR

259: CJC sensor

Fault cold junction compensation sensor

AR

261: Loss of Engine flame

No flame after five ignition tries in Engine

UR

262: Loss of Supplementary flame

No flame after five ignition tries in Supplementary

UR

263: Engine BCU failure

Multiple communication request of Engine Burner Control Unit

unsuccessful.

1) Failure caused by BCU

ARP

2) BCU Communication Timeout on Main Control Board

AR

264: Supp. BCU failure

Multiple communication request of Supp. Burner Control Unit

unsuccessful.

1) Failure caused by BCU

ARP

2) BCU Communication Timeout on Main Control Board

AR

265: BCU failure

Not supported in Main Control Board

270: excessive temp. diff.

Excessive max temperature difference across the heat exchanger

during 5 minutes or excessive limit temperature difference.

If temperature difference fell below (threshold - switching

differential boiler): automatic reset

- when the maximum setting was exceeded immediately

AR

AR

- when the limit value was exceeded after 10 minutes

AR 10’

274: Dry fire protection

Flow switch did not close within 4 minutes

UR

UR

278: Max Temp Rise

Maximum flow temperature rise exceeded, automatic reset after

10 minutes

AR 10’

11.1

List of Error Codes

In the table below: - PCB = Main Control Board, BCU = Burner Control Unit.

UR = User Reset, AR = Automatic Reset, ARP = Automatic Reset after Power Down

NOTE: An automatic reset is only done if the fault condition has cleared.

• After 10 minutes or after down power (ARP)

+ Will clear message if 65°C is achieved - does not inhibit appliance on.