0 error codes – Baxi Potterton ECOGEN 24/1.0 User Manual
Page 18
11.0 Error Codes
18
© Baxi Heating UK Ltd 2010
Error code: Display
Description
Lockout/Reset action
Eng
Sup
10: Outside sensor
Fault outside temp sensor1
AR
AR
20: Boiler flow sensor
Fault boiler flow temp sensor
AR
AR
40: Boiler return sensor
Fault return temp sensor boiler
AR
AR
50: DHW tank sensor
Fault DHW1 sensor
AR
AR
60: Room sensor 1
Fault room temp sensor HC1
AR
AR
65: Room sensor 2
Fault room temp sensor HC2
AR
AR
83: BSB short-circuit
Boiler system bus short-circuit
AR
AR
84: BSB address collision
More then 1 room units are assigned to the same HC
Assign one of them to HC2 or assign QAA7x not as room unit
AR
AR
85: Radio communication
Communication to radio device interrupted
AR•
AR•
91: Data loss in EEPROM
Failure in Class B-SW: Irreparable data loss in EEPROM
NRP
NRP
92: Device electronics error
RAM failure, HBC processor register failure, blocking chain
undefined (toggling), safety chain discrepancy.
Reset: Press Service Reset within 20 seconds after Power up
NRP
NRP
95: Time of day invalid
The real time clock unit detected corrupted time of day.
96: Minor SW failure
Failure in Class B-SW: Stack overflow or program sequence failure
AR
AR
97: SW or HW failure
Failure in EGC-SW which causes non-volatile lock.
NRP
NRP
127: Legionella temperature
Legionella temperature not achieved within 48 hours
AR+
AR+
157: Boiler Flow Overheat stat
Boiler flow overheat thermostat / safety chain open
UR
UR
158: Condensate
Condensate switch of safety chain opened
UR
UR
164: Flow
Low flow or faulty flow switch
AR
AR
257: Pack sensor
Fault pack temp sensor
258: Pack over- temp
Internal ambient temperature to high
AR
AR
259: CJC sensor
Fault cold junction compensation sensor
AR
261: Loss of Engine flame
No flame after five ignition tries in Engine
UR
262: Loss of Supplementary flame
No flame after five ignition tries in Supplementary
UR
263: Engine BCU failure
Multiple communication request of Engine Burner Control Unit
unsuccessful.
1) Failure caused by BCU
ARP
2) BCU Communication Timeout on Main Control Board
AR
264: Supp. BCU failure
Multiple communication request of Supp. Burner Control Unit
unsuccessful.
1) Failure caused by BCU
ARP
2) BCU Communication Timeout on Main Control Board
AR
265: BCU failure
Not supported in Main Control Board
270: excessive temp. diff.
Excessive max temperature difference across the heat exchanger
during 5 minutes or excessive limit temperature difference.
If temperature difference fell below (threshold - switching
differential boiler): automatic reset
- when the maximum setting was exceeded immediately
AR
AR
- when the limit value was exceeded after 10 minutes
AR 10’
274: Dry fire protection
Flow switch did not close within 4 minutes
UR
UR
278: Max Temp Rise
Maximum flow temperature rise exceeded, automatic reset after
10 minutes
AR 10’
11.1
List of Error Codes
In the table below: - PCB = Main Control Board, BCU = Burner Control Unit.
UR = User Reset, AR = Automatic Reset, ARP = Automatic Reset after Power Down
NOTE: An automatic reset is only done if the fault condition has cleared.
• After 10 minutes or after down power (ARP)
+ Will clear message if 65°C is achieved - does not inhibit appliance on.