10. Setting Up NetScout Manager Plus for FrameSaver Devices

10-14

September

2002

9128-A2-GB20-80

Procedure

1. Open a terminal window and go to $NSHOME/usr.

2. Copy an example or interface-specific file to a new file that contains the user

history table number.

3. Open the new file using a text editor.

The variables in the file are listed with their OIDs (Object IDs). The frame relay
interface number 101015001 must replace @IFN, and the DLCI number to be
monitored must replace @DLCI.

Example: frCircuitSentFrames
Change “

1.3.6.1.2.1.10.32.2.1.6.@IFN.@DLCI

to “

1.3.6.1.2.1.10.32.2.1.6.101015001.301

The only valid interface number for a FrameSaver SLV 9126, 9126-II, 9126-II
Router, or 9128-II is 101015001.

4. Edit the new file, as needed.

Refer to

Creating .UDH Files and Using Custom History in the NetScout Manager

Plus User Guide for additional information.

See

Appendix B,

SNMP MIBs and Traps, and RMON Alarm Defaults

, for OID

information for an interface.