Planar EL320.240-FA3 User Manual
Planar Sensors
Advertising
Table of contents
Document Outline
- EL320.240-FA3 Multi-Color QVGA Display
- Installation and Set-up
- Specifications and Operation
- Environmental
- Over-temp Condition
- The display contains a temperature sensor which measures the temperature of the circuit board at the lower left corner as viewed from the component side of the board.
- If the board temperature exceeds approximately 100C, the display will automatically operate at its lowest luminance setting (as if LUM0 was low and LUM1 was high) to reduce the board temperature. At no point will the display be shut down. The content of the pattern will be unaffected.
- After surpassing 100C, once the board temperature drops below approximately 92C or the power is cycled, the display will resume normal operation as defined by the LUM0 and LUM1 settings. Typically, the 100C limit may be reached if the 12V input power exceeds 6W when the ambient temperature for the display electronics is 85C.
- Optical
- Power
- The supply voltage and power requirements are shown in the table below. The power will vary greatly depending on the number of pixels lit and depending on the chosen luminance level (see graph below.) Power levels will vary up to +/-15 % from display to display due to brightness variation.
- Connector
- Dimming
- Self Test Mode
- Reliability
- Safety and EMI Performance
- Mechanical Characteristics
- Display Dimensions and Component Envelope