Operation – Porter-Cable D26729-028-0 User Manual

Page 11

Advertising
background image

11- ENG

D26729

OPERATION

KNOW YOUR GENERATOR

Read this General Manual and Safety Rules before operation of your Generator.
Compare the illustration in your parts manual with your generator to familiarize yourself with
the location of various controls and adjustments. Save all manuals for future references.

GENERATOR CAPACITY

IMPORTANT: Exceeding the rated capacity of your generator can result in serious damage
to your generator and connected electrical devices. See the Wattage Calculation section in
this manual to assist you in determining the appliances and tools that can be run with the
wattage capacity of your generator.

CIRCUIT BREAKERS

Each receptacle has a circuit breaker to protect the generator from overloading. If the circuit
breaker trips, unplug all electrical loads from the generator. Let the circuit breaker cool
down. Push circuit breaker button to reset.

LOW OIL SHUTDOWN

Your generator engine is equipped with Low Oil Shutdown. Low Oil Shutdown is
a safety device designed to protect your engine from damage in the event the oil
level in the crankcase is low.

If while the engine is running, the oil gets low, it will automatically shut itself
down and will not restart until the oil is added. If the oil is low before start-up,
the generator will not start until oil is added.

NOTE: The Low Oil Shutdown mechanism is very sensitive. You must fill the
engine to the full mark on the dipstick to inactivate this safety device.

BEFORE START UP

This generator has been shipped from the factory without oil in the
crankcase. Operating the unit without oil can damage the engine.

Always check engine oil level before every start. Running engine low
of oil or out of oil could result in serious damage to the engine.

Follow the steps listed below before starting generator:

1.

Check engine oil. Refer to the Engine Operator's Manual for
correct grade and quantity of oil.

2.

Check fuel level, fill as required. Make sure generator is
turned off and has been allowed time to cool down. Use
clean, fresh, regular unleaded gasoline with a minimum of
87 octane. Do not mix oil with gasoline.

Never fill fuel tank completely. Fill tank to
1/2" below the bottom of the filler neck to

provide space for fuel expansion. Wipe any fuel spillage from engine and equipment
before starting engine.

Never fill fuel tank indoors. Never fill fuel tank when engine is
running or hot. Do not smoke when filling fuel tank.

Never run engine indoors or in enclosed, poor ventilated areas, en-

gine exhaust contains carbon monoxide, an odorless and deadly gas.

3.

Make sure generator is grounded in accordance with local requirements.

4.

All electrical loads MUST be disconnected.