Solid State Thermostat Field Calibration 

If field calibration is necessary, follow these steps:

 Allow appliance to heat to set point, and allow 30 minutes to stabilize.
 Measure the vat center oil temperature. Compare this with the knob pointer scale.
 To reposition the knob, pry off the cap of the knob with a sharp knife blade.
 Without turning the shaft, loosen the 5/16-compression nut and pull the knob off.
 Re-install the knob with the pointer at the temperature indicated on the test thermometer.
 Tighten the 5/16-compression nut, and install cap.