National Instruments NI 9472 User Manual
Page 18
NI 9472/9474
18
ni.com
Output impedance (R
0
)
Typical ........................................ 0.07
Ω
Maximum ................................... 0.13
Ω
Continuous output current (I
0
), per channel
NI 9472....................................... 0.75 A max
NI 9474....................................... 1 A max
Output voltage (V
0
) ........................... V
sup
– (I
0
· R
0
)
I/O protection
Voltage........................................ 30 VDC max
Reversed voltage ........................ None
Short-circuit behavior
Short-circuit trip time ................. 10
μs at 13 A
Current
Channel Behavior
Module Protection
0 to 1 A
Channel does not trip
Module is not damaged
1 to 6 A
Channel does not trip
Module may be damaged
6 to 13 A
Channel may trip
Module may be damaged
>13 A
Channel trips
Module is not damaged