Accessories, Specifications, Accessories specifications – National Instruments NI 6509 User Manual

Page 19: Power requirements, Digital i/o

Advertising
background image

© National Instruments Corporation

19

NI 6509 User Guide and Specifications

Accessories

National Instruments offers the following products for use with the
NI 6509.

For more information about optional equipment available from National
Instruments, refer to the National Instruments catalog or visit

ni.com

.

Specifications

This section lists the specifications for the NI 6509. These specifications
are typical at 25 °C, unless otherwise noted.

Power Requirements

Power consumption (typical) ................. 375 mA on +3.3 VDC

No load current....................................... 250 mA on +5 VDC

With a load, use the following equation to determine the power
consumption on a 5 V rail. In the equation, j is the number of channels
you are using to source current.

Power available at I/O connector ........... 1 A (fused), maximum

(combined or individually)

Note

The voltage at the I/O connector is dependent upon the amount of current drawn

from the NI 6509 device.

Digital I/O

Number of channels ............................... 96 I/O

Compatibility ......................................... TTL/CMOS

Cable (Part Number)

Accessory (Part Number)

SH100-100-F shielded cable (185095)

SCB-100 connector block (776990)

R1005050 ribbon cable (182762)

CB-50 connector block, DIN-rail mount (776164)

CB-50LP connector block, panel mount (777101)

250 mA

i

1

=

j

current sourced on channel i

(

)

+

Advertising