Carbon is being
deposited on
glass, logs or
c o m b u s t i o n
chamber sur-
faces.

Flame is impinging on the
logs or combustion cham-
ber.

- check that the logs are correctly positioned.
- open air shutter to increase the primary air.
- check the input rate: check the manifold pressure and orifice size
as specified by the rating plate values.
- check that the door gasketing is not broken or missing and that the
seal is tight.
- check that both 5" and 8" vent liners are free of holes and well
sealed at all joints.
- check that minimum rise per foor has been adhered to for any
horizontal venting.

Air shutter has become
blocked

- ensure air shutter opening is free of lint or other obstructions.

Flames are con-
sistently too large
or too small.
Carboning occurs.

- check pressure readings:
Inlet pressure can be checked by turning screw (A) counter-clock-
wise 2 or 3 turns and then placing pressure gauge tubing over the
test point. Gauge should read 8" (minimum 4.5") water column for
natural gas or 13" (11" minimum) water column for propane. Check
that main burner is operating on "HI".
Outlet pressure can be checked the same as above using screw (B).
Gauge should read 3.5" water column for natural gas or 10" water
column for propane. Check that main burner is operating on "HI".
AFTER TAKING PRESSURE READINGS, BE SURE TO TURN
SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT
OVERTORQUE.
Leak test with a soap and water solution.

Unit is over-fired or under-
fired.

P

I

A

B

PILO

T

N O

L

O

T

H I

LO

FF O

Main burner flame
is a blue, lazy,
t r a n s p a r e n t
flame.

Blockage in vent.

- remove blockage. In really cold conditions, ice buildup may occur
on the terminal and should be removed as required.

Incorrect installation.

- refer to Figure 34 to ensure correct location of storm collars.

White / grey film
forms.

Sulphur from fuel is being
deposited on glass, logs or
combustion chamber sur-
faces.

- clean the glass with a recommended gas fireplace glass cleaner.
Do not clean glass when hot!
If deposits are not cleaned off regularly, the glass may become per-
manently marked.

Exhaust fumes
smelled in room,
headaches.

Fireplace is spilling.

- check door seal and relief flap seal.
- check for chimney blockage
- check that chimney is installed to building code.
- room is in negative pressure; increase fresh air supply.

Pilot goes out
when the gas knob
is released.
The gas valve has
an interlock de-
vice which will not
allow the pilot
burner to be lit
until the thermo-
couple has
cooled. Allow ap-
proximately 60
seconds for the
thermocouple to
cool.

System is not correctly
purged.

- purge the gas line with a glass door open.

Out of propane gas.

- fill the tank.

Pilot flame is not large
enough

- turn up the pilot flame.

- gently twist the pilot head to improve the flame pattern around the
thermocouple.

Pilot flame is not engulfing
the thermocouple.
Thermocouple shorting /
faulty.

- loosen and tighten thermocouple.
- clean thermocouple and valve connection.
- replace thermocouple.
- replace valve.

Faulty valve.

- replace.

(vertical vent)

TROUBLE SHOOTING GUIDE

B

EFORE

ATTEMPTING

TO

TROUBLESHOOT

,

PURGE

YOUR

UNIT

AND

INITIALLY

LIGHT

THE

PILOT

AND

THE

MAIN

BURNER

WITH

THE

GLASS

DOOR

OPEN

.

SYMPTOM

PROBLEM

TEST SOLUTION