Raritan Computer SCS232 User Manual

Page 17

Advertising
background image

C

HAPTER

4: I

NSTALLATION

9

P

OWER

O

N

1. With your user consoles and devices attached, connect the supplied AC power cord to ConsoleSwitch, and

switch the power on. Note that terminals and devices may be attached or disconnected at any time.

2. On the bottom-left of your user console, you will see a message directing you to type

H

to access the

main help menu. (Note: if you attach a user console after ConsoleSwitch has already been powered on, you
will not see this message). Type

H

to access the main menu, entitled “Raritan ConsoleSwitch

Commands”.

3. The following menu will be displayed:

Raritan Console Switch Commands (SCS232 v0A2)

H

Main Help Menu

V

View Stored Data

U#

Configure Communications for User 1 or 2

D#

Configure Communications for Device 1 - 32

N#

Name Device 1 - 32

C

Select Channel

D

Display All Channels

S

Scan Menu

F

Update Firmware

Press CTRL+G to Enter/Exit HotKey Mode

Figure 6.

Main Menu

C

ONFIGURING

C

HANNEL

N

AMES AND

S

ETTINGS

For each channel to which you have attached a device, perform the following actions:

1. Type

N#

(where

#

is the channel number of the attached device). Assign an appropriate name to the

device connected to that channel (e.g. “WWW1-NETRAT1”), and press

. Channel names may be up to

12 characters in length; they are stored in non-volatile memory, and will therefore be maintained even if
ConsoleSwitch is powered off.

2. If the device is set to 9600 Baud, No Parity, 8 Data Bits, 1 Stop Bit; then you are finished configuring the

channel; proceed to the next device.

3. If the device is not set to 9600 Baud, No Parity, 8 Data Bits, 1 Stop Bit; then type

D#

(where

#

is the

channel number of the attached device) to enter the communications setting menu. Using the menu,

change any parameter that needs to be altered in order to match your device’s communication settings.

Communication Setup:

B

Set Baud Rate

W

Set Word Length (No. of Data Bits)

P

Set Parity

S

Set No. of Stop Bits

F

Set Flow Control

R

Reset all Settings to Default Values
Defaults: 9600 Baud, 8 Data Bits, No Parity, 1 Stop

Bit.
H

Exit to Main Menu

Figure 7.

Communications Setup Menu

It is important to realize that configuring these communications settings affects ConsoleSwitch’s device
port only, not the external device. ConsoleSwitch communications settings should be changed to match

the settings of connected terminals and devices.

4. Type

H

to return to the main menu.


After configuring each device channel port, proceed to the next section.

C

ONFIGURING

U

SER

C

ONSOLE

C

OMMUNICATIONS

S

ETTINGS