Installation, Wiring diagram – Recoton/Advent U31-LP2 User Manual
Page 16
16
FPI U31-2 Gas Fireplace Insert
INSTALLATION
WIRING DIAGRAM
CAUTION: Label all wires prior
to disconnection when servicing
controls. Wiring errors can cause
improper and dangerous opera-
WARNING: Electrical Grounding Instructions
This appliance is equipped with a three pronged (grounding) plug for your protection against shock hazard and should
be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from
this plug.
This heater does not require a 120V A.C. sup-
ply for operation. In case of a power failure, the
burner switch and the optional remote control/
thermostat will continue to operate. However,
a 120V A.C. power supply is needed for the
fan/blower operation.
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
Slots
Push Screen
Door down
fi rmly
to lock into
place.
3) Open Bottom Louvers.
4) Remove the bottom glass trim.
Discard both top & bottom glass trim.
5) Replace the glass and secure with the two
glass clips. Do not over tighten as this could
break the glass.
Make sure the glass is centered.
6) Insert side hooks on the double screen
door into the 4 slots between the faceplate
and the glass and lower assembly into the
locking position. Push down fi rmly with both
hands to lock into place.
Side Hook
Insert Screen Door
hooks into the 4
slots between the
faceplate and the
fl ush door.