Power strip status, Cli command for power control, Cli port power association – Raritan Computer DOMINION DSX-0N-E User Manual
Page 178: Figure 99 power strip status
160
D
OMINION
SX
U
SER
G
UIDE
Power Strip Status
Click Power Strip Status on the Power Control menu to check power strip status.
Figure 99 Power Strip Status
CLI Command for Power Control
CLI Port Power Association
Description: Power Control menu – Associate a power strip outlet to a DSX port
Scenario #1
Port Power Association – Add Outlet.
Pre-condition
Administrator user is logged in via CLI.
Power Strip device (DPX) is physically connected to DSX named
PowerStr1.
User is in power menu.
Action 1.
Type command.
2.
Press Enter.
CLI Input
Command: associate port 1 powerstrip PowerStr1 outlet 1
Scenario #2
Port Power Association – Associate 6 Outlets to one Port.
Pre-condition
Administrator user is logged in via CLI.
Power Strip device (DPX) is physically connected and configured to DSX
named PowerStr1.
User is in power menu.
Action 1.
Type command - associate [port port] [powerstrip powerstrip] [outlet
outlet] to associate Outlet1 to Port1
2.
Press Enter.
3.
Repeat steps 3 and 4 for Outlet 2, 3, 4, 5 and 6.
CLI Input
associate port 1 powerstrip PowerStr1 outlet 1-6