Technical specifications, Power supply specifications, Failsafe relay contact ratings – RuggedCom RS416 User Manual

Page 36: 6 technical specifications, 1 power supply specifications, 2 failsafe relay contact ratings

Advertising
background image

Technical Specifications

36

RuggedCom

®

RuggedServer™ RS416 Family Installation Guide rev118

6 Technical Specifications

6.1 Power Supply Specifications

Power Supply Type

4

Input Range

Internal

Fuse

Rating

Max. Power

Consumption

3

Min

Max

12 – 24 VDC

10 VDC

36 VDC

6.3A(F)

2

15 W

48 VDC

36 VDC

59 VDC

3.15A(T)

2

HI (125/250 VDC)

1

HI (110/230 VAC)

1

88 VDC

85 VAC

300 VDC
264 VAC

2A(T)

1,2

Table 13: Main Power Supply Specifications

Power Supply Type

(PS2)

4

Input Range

Internal

Fuse

Rating

Maximum Power

Consumption

Min

Max

48 VDC

37 VDC

72 VDC

2A(T)

2

68 W

Table 14: PoE Power Supply Specifications

NOTES:

1. This is the same power supply for both AC and DC.
2. (F) Denotes fast-acting fuse, (T) denotes time-delay fuse.
3. Power consumption varies based on configuration. 10/100Tx ports consume

roughly 1W less than fiber optic ports

4. RS416 can use the Main Power Supply for PS1 and optionally PS2. RS416P

uses the Main Power Supply in PS1 only and the PoE Power Supply in PS2 only.

6.2 Failsafe Relay Contact Ratings

Parameter

Value (Resistive Load)

Max Switching
Voltage

240VAC, 125VDC

Rated Switching
Current

2A @ 240VAC
0.15A @ 125VDC, 2A @ 30VDC

Max Switching
Capacity

150W, 500VA

Table 15: Failsafe Relay Contact Ratings

Advertising