FPI P36-4 Zero Clearance Direct Vent Gas Fireplace

24

Horizontal Venting with Three (3) 90

o

Elbows

One 90

o

elbow = Two 45

o

elbows.

H

H1

V

Horizontal Venting with Two (2) 90

o

Elbows

One 90

o

elbow = Two 45

o

elbows.

Option

V

H + H1

W i t h t h e s e o p t i o n s ,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.

Please note minimum 1
foot between 90

o

elbows

is required.

A)

0' Min.

2' Max.

B)

1' Min.

3' Max.

C)

2' Min.

4' Max.

D)

3' Min.

5' Max.

E)

4' Min.

6' Max.

F)

5' Min.

7' Max.

G)

6' Min.

8' Max.

Lengths do not include

elbow indicated

Option

V

H

V + V1

H + H1

With these options,
max. total pipe
length is 30 feet
with min. of 12 feet
total vertical and
max. 9 feet total
horizontal.

Please note min. 1
foot between 90

o

elbows is required.

A)

0' Min.

1' Max.

1' Min.

2' Max.

B)

1' Min.

2' Max.

3' Min.

3' Max.

C)

2' Min.

2' Max.

5' Min.

4' Max.

D)

3' Min.

2' Max.

7' Min.

5' Max.

E)

4' Min.

3 Max.

9' Min.

6' Max.

F)

5' Min.

4' Max. 10' Min. 7' Max.

G)

6' Min.

5' Max. 11' Min. 8' Max.

H)

7' Min.

6' Max. 12' Min. 9' Max.

Lengths do not include elbow indicated