Opticon NFT 2100 User Manual

Page 65

Advertising
background image

Manual No. 25-ULNFT2100-01; Mar, 2005 NFT 2100 CCD Fixed Mount Barcode

Scanner

Page 62

31. Redundant Decoding

The Number of Redundant Decodes determines how many times the scanner must decode a bar code

and obtain the same value before it will transmit the data. For example, if the redundancy is set at three

times, the scanner will not transmit data until it has completed three consecutive, identical “good reads”.

In the case of a poor label which generates an intermediate “no decode” within a sequence of four scans

where three of the four have resulted in “good reads”, the scanner will transmit the data after the fourth

scan. In other words, a “no decode” does not restart the sequence.

Computer

Command

Function

/Description

Bar Code

Command

(ZZ)

START/END

Programming Menu

[[

X2

Read bar code three times

Y3

%

X3

Read bar code four times

Y!

32. Transmitting Error Indications

Computer

Command

Function

/Description

Bar Code

Command

(ZZ)

START/END

Programming Menu

[[

WD

Disable ACK/NAK response to

sent command

XE

%

WC

Enable OK=ACK, ERROR=NAK,

response to sent command

XD