7.3.3.

Tilt Angle

Scanning performance is guaranteed when γ ≤ ±20°

Figure 6: Tilt angle

Conditions

Barcode Sample: OPTOELECTRONICS Test Sample

Distance:

70 mm from the front edge of the scanner

Label:

Pitch, Skew Angle, Dead Zone
PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code-39,
Quiet Zone = 10 mm, N/W Ratio = 1:2.5
Tilt Angle
PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm

Angles:

Pitch angle:

Skew angle: β = +15°, Tilt angle: γ = 0°

Tilt angle:

Pitch angle: α = 0°, Skew angle: β = +15°

Skew angle, Dead zone

: Pitch angle: α = 0°, Tilt angle: γ = 0°

Curvature: R

=