VENTING - RESTRICTOR PLACEMENT

NOTE: Vent restrictors are designed to reduce vertical stack action for vent
terminations which will reduce the velocity of incoming combustion air and
not adversely affect the standing pilot or the efficiency of the appliance.

RESTRICTOR PLACEMENT FOR SIDEWALL VENTED APPLICATIONS ONLY

WARNING: These restrictors are only to be installed in the vent system if the vent exceeds 10’ in

vertical height. See below which restrictor to use.

Installing them under any other circumstances may cause hazardous venting
conditions and may result in personal injury, property damage or death.

NOT FOR USE IN VERTICALLY VENTED APPLICATIONS

Restrictor Number #1

Sidewall Venting - Above

Ten Feet (10’)

Restrictor Number #2

Sidewall Venting - Above

Eighteen Feet (18’)

Archgard System

Archgard System

In the Archgard system, the

restrictors are placed on the

exhaust outlet on the appliance.

Simpson Dura-Vent

Simpson Dura-Vent

With Simpson Dura-Vent,

locate the restrictor in the exhaust

section fitting into the formed lip.