Understanding the Code Format
To understand and modify the Code format according to a specific central station see the
following
•
First digit: determine the number corresponding to the desired combination of:
Kissoff/Handshake Freq / Message Validation / Extended–Non-Extended Format)
•
Second digit: determine the number (or letter) corresponding to the desired combination
of: Dialing Rate / Interdigit Time / Data Frequency
Location: 27
CS Protocols: (1
st
Digit):
1
st
Digit
Format
Kissoff/Handshake Freq
Message Validation
0
(default)
Non-Extended
1400 Hz
Dual Round Compare
1
Non-Extended
2300 Hz
Dual Round Compare
2
Non-Extended
1400 Hz
Parity
3
Non-Extended
2300 Hz
Parity
4
Extended
1400 Hz
Dual Round Compare
5
Extended
2300 Hz
Dual Round Compare
6
Extended
1400 Hz
Parity
7
Extended
2300 Hz
Parity
Location: 27
CS Protocols: (2
nd
Digit):
2
nd
Digit
Data Rate
Interdigit Time
Data Frequency
0
(default)
40 pulses/sec
390 ms
1800 Hz
1
33 pulses/sec
390 ms
1800 Hz
2
20 pulses/sec
390 ms
1800 Hz
3
10 pulses/sec
390 ms
1800 Hz
4
40 pulses/sec
650 ms
1800 Hz
5
33 pulses/sec
650 ms
1800 Hz
6
20 pulses/sec
650 ms
1800 Hz
7
10 pulses/sec
650 ms
1800 Hz
8
40 pulses/sec
390 ms
1900 Hz
9
33 pulses/sec
390 ms
1900 Hz
A
20 pulses/sec
390 ms
1900 Hz
B
10 pulses/sec
390 ms
1900 Hz
C
40 pulses/sec
650 ms
1900 Hz
D
33 pulses/sec
650 ms
1900 Hz
E
20 pulses/sec
650 ms
1900 Hz
F
10 pulses/sec