Installation Procedure ____________________________________________________________

To assure maximum performance from your 800S series sprinklers, read these instructions
completely prior to installation or service.

Constructing Swing Joints

1. Construct or provide triple swing joints for each sprinkler as shown in Figure 1. Use PVC or

ABS pipe nipple for the sprinkler connection.

Note: On sites where the possibility of heavy equipment rolling over a sprinkler exists, the
swing joint will flex preventing damage to the lateral or main lines. On a new installation in raw
ground where the sprinklers are to be initially installed above the finished grade and lowered
when new turf is established, the swing joint allows sprinkler repositioning without changing
risers.

2. Flush lines thoroughly prior to installing sprinkler.

3. Apply Teflon™ tape on riser threads (not required on ACME threads). Install sprinkler to the

riser and tighten.

CAUTION: Use only Teflon tape on riser threads. Use of pipe dope or other types of sealing compounds can cause

deterioration of sprinkler body threads.

Connecting Control Wires (Electric Models Only)

1. Route control wires to sprinklers. Provide extra wire at sprinkler to allow for height adjustment. One common wire and station wire

is required for each sprinkler. See Wire Sizing Chart, Table 1 for proper application.

Note: Wire length data provided in Table 1 is the sum
of the station and common wire legs. See example in
Figure 2.

2. Attach control wires to solenoid leads using an

approved waterproof splicing method.

CAUTION: All wire splices and field connections

must be waterproofed to prevent short circuit to
ground and subsequent controller damage.

A U

T O

O N

O F F

Figure 1

Voltage AWG

mm

2

Voltage Drop

Circular Mils

1 Sprinkler

Total Wire Length Between Controller and Sprinkler

2 Sprinklers

3 Sprinklers

4 Sprinklers

23

14/14 2.5/2.5

2.5/4.0
2.5/5.5
4.0/4.0
4.0/5.5
4.0/7.0
5.5/5.5
2.5/2.5
2.5/4.0
2.5/5.5
4.0/4.0
4.0/5.5
4.0/5.5

4

4100

6571'

2003 m
2596 m
3541 m
3190 m
4135 m
5625 m
5080 m
2503 m
3245 m
4427 m
3987 m
5168 m
7031 m
6350 m

1001 m
1298 m
1771 m
1595 m
2067 m
2812 m
2540 m
1252 m
1623 m
2213 m
1993 m
2584 m
3515 m
3175 m

668 m
865 m
1180 m
1063 m
1378 m
1875 m
1693 m
835 m
1082 m
1476 m
1329 m
1723 m
2344 m
2117 m

501 m
649 m
886 m
798 m
1034 m
1406 m
1270 m
626 m
812 m
1107 m
997 m
1292 m
1758 m
1581 m

3285'

2190'

1643'

23

14/12

4

5315

8518'

4259'

2839'

2129'

23

14/10

4

7250

11619'

5809'

3873'

2905'

23

12/12

4

6530

10465'

5232'

3488'

2616'

23

12/10

4

8465

13566'

6783'

4522'

3391'

23

12/8

4

11515

18454'

9227'

6151'

4613'

23

10/10

4

10400

16667'

8333'

5556'

4167'

24

14/14

5

4100

8213'

4107'

2738'

2053'

24

14/12

5

5315

10647'

5324'

3549'

2662'

24

14/10

5

7250

14523'

7262'

4841'

3631'

24

12/12

5

6530

13081'

6540'

4360'

3270'

24

12/10

5

8465

16957'

8479'

5652'

4239'

24

12/8

5

11515

23067'

11533'

7689'

5767'

24

10/10

5.5/5.5

5

10400

20833'

10417'

6944'

5208'

Table 1: Wire Sizing Chart

Figure 2

Station Wire = 1095' (334m)

Common Wire = 1095' (334m)

Total Wire Length = 2190' (668m)

835S and 855S Series Rotary Sprinklers

Installation & Service Instructions