Debug commands, Special commands – TANDBERG D1320202 User Manual

Page 27

Advertising
background image

TANDBERG GW

Data port Command Interface User Guide

27

LastCorrection: 1
*s/end


4.2.4. Debug Commands


Command: Desription:
Syslog

Enables a real-time log of Bonding, H.221 and H.323, H324m, ISDN, RTSP, IVider,
SIP and IVider Engine activity.

Note! Logging via the serial port is limited by the speed of the serial port, which
might result in loss of logging data. Therefore, it is advised to use Telnet instead.


Syslog <Level> <Mask>

Level [0..3]: no logging when level = 0

Mask: With this Mask the logging of different components can be turned on. The
mask has to be used as a bit mask.

FREYALOGH324m 1
FREYALOGH323 2
FREYALOGISDN 4
FREYALOGRTSP 8
FREYALOGIVID 16
FREYALOGSIP 32
FREYALOGENGI 64

For instance to view the logging of the H324m, SIP and IVider components, the mask
value equals 1 + 16 + 32 = 49


4.2.5. Special Commands


Command: Description:
Boot

Reboots the system.

xCommand Boot

DefaultValuesSet

This command is used to restore factory default settings. Issuing this command
with no parameters will restore all settings except network settings and option
keys.

DefaultValuesSet Level: <1 .. 3>


Example (restore all default factory setting):

xCommand DefaultValuesSet

*r Result (status=OK): /
*r/end

OK

FeedbackRegister

Command used to instruct the system to return XML feedback over HTTP(S)
to specific URLs. What parts of the Status and Configuration XML documents
to monitor are specified by XPath expressions. The system supports issuing

Advertising