23

timing requirements over recommended operating conditions (see Note 3)

MIN

NOM

MAX

UNIT

t

c(C)

CLKIN cycle time

195

597

ns

t

f(CI)

CLKIN fall time

10

ns

t

r(CI)

CLKIN rise time

10

ns

t

w(CIL)

CLKIN low pulse duration, t

c(CI)

= 50 ns (see Note 4)

40

ns

t

w(CIH)

CLKIN high pulse duration, t

c(CI)

= 50 ns (see Note 4)

40

ns

t

su(S)

SYNC setup time before CLKIN low

10

Q -- 10

ns

t

h(S)

SYNC hold time from CLKIN low

15

ns

Value derived from characterization data and not tested.

NOTES: 3. Q = 1/4t

c(C)

.

4. CLKIN duty cycle [t

r(CI)

+ t

w(CIH)]

/ t

c(CI)

must be within 40-60%.

C

L

= 100 pF

2.15 V

R

L

= 825

Test

Point

From Output

Under Test

Figure 3. Test Load Circuit

0.80 V

0.92 V

1.88 V

2.0 V

0

V

IH

(Min)

V

IL

(Max)

(a) Input

0.6 V

0.8 V

2.2 V

2.4 V

0

V

OH

(Min)

V

OL

(Max)

(b) Output

Figure 4. Voltage Reference Levels