13. RACK MOUNTING

Use the optional MB-23B Rack Mounting Bracket when mounting the Network Video Recorder in an
equipment rack. Remove 4 rubber feet on the bottom surface by loosening their respective fixing screws with
a standard screwdriver.

Notes
• Use the Network Video Recorder in locations with ambient temperature of between 0°C and +40°C.
• Be sure to mount the Network Video Recorder below the heat generating components, and mount the

perforated panel between the Recorder and such a heat generating component as required.

• The Network Video Recorder has a built-in cooling fan. Never block the Recorder’s ventilation slot.
• Avoid installing the Network Video Recorder in locations exposed to vibration.

a) Elevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, the operating

ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration
should be given to installing the equipment in an environment compatible with the manufacturer's maximum
rated ambient temperature (Tmra).

b) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow

required for safe operation of the equipment is not compromised.

c) Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is

not achieved due to uneven mechanical loading.

d) Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit

and the effect that overloading of circuits might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

e) Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained. Particular attention

should be given to supply connections other than direct connections to the branch circuit (e.g., use of power
strips).