Technical specifications

13

Technical specifications

Power requirements

Over-current protection

Ensure the supply to this unit is protected by a branch circuit protector rated by a
maximum of 20A.

Operating environment

The IP GW must only be used within the following environmental conditions:

Anti-static precautions

When servicing or removing components or connections, first attach an anti-static
wrist strap to an appropriate earth point.

Table 2: IP GW ratings

Rating

Value

Nominal voltage

115V to 230V 50/60 Hz

Current rating

2A Maximum

Supply voltage range

100 to 240V 50/60 Hz

Caution — over-current devices must meet applicable national and local
electrical safety codes and be approved for the intended application.

Table 3: Operating environment

Environment

Temperature

Humidity

Operating environment

0°C to 35°C

10% to 95%
(non-condensing)

Non-operating environment

-10°C to 60°C

10% to 95%
(non-condensing)

Optimum operating environment

21°C to 23°C

45% to 50%
(non condensing)

!