Vivotek IP7133/IP7134 User Manual
Page 75
VIVOTEK - A Leading Provider of Multimedia Communication Solutions
User's Manual - 75
Group: event_i<0~2>
PARAMETER
VALUE
SECURITY
(get/set)
DESCRIPTION
name
string[40]
6/6
The identification of this entry
enable
0, 1
6/6
To enable or disable this event.
priority
0, 1, 2
6/6
Indicate the priority of this event.
“0” indicates low priority.
“1” indicates normal priority.
“2” indicates high priority.
delay
1~999
6/6
Delay seconds before detect next event.
trigger boot,
di,
motion,
seq,
6/6
Indicate the trigger condition.
“boot” indicates system boot.
“di” indicates digital input.
“motion” indicates video motion detection.
“seq” indicates periodic condition.
di
<integer>
6/6
Indicate which di detected.
This field is required when trigger condition
is “di”.
One bit represents one digital input. The LSB
indicates DI 0.
mdwin <integer>
6/6
Indicate
which motion detection windows
detected.
This field is required when trigger condition
is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
inter
1~999
6/6
Interval of period snapshot in minute.
This field is used when trigger condition is
“seq”.