Summary, Serial port setting – Vax RS 232C User Manual
Page 3
Page 3 of 24
1. SUMMARY
The RS-232C protocol described in this document is designed to be used to control the
9000 Series Amplifier from a PC and/or remote controller. This specification applies to the
9000 Series firmware version 3.10 or later.
Settings that can be controlled are as follows:
•
Channel fader gain
•
Crosspoint gain (Mixer mode only)
•
Preset memory recall
•
Channel ON/OFF
•
Power ON/OFF
•
Tone control (Bass/Treble)
•
EQ settings (ON/OFF, Band number selection, Gain setting, Q setting, Center frequency setting)
•
Loudness compensation settings
•
Filter settings (High Pass Filter/Low Pass Filter)
•
Input sensitivity setting
•
Phantom power setting
Following values can be read from the 9000 Series Amplifier.
•
Channel name
When connecting the PC and/or remote controller to the 9000 Series Amplifier using this protocol,
set the 9000 Series Amplifier’s RS-232C port as follows:
Bit rate: 9,600/19,200/38,400/57,600 bps (Select the band rate depending on the
remote controller to be connected.) (See; Operating instructions of the 9000
Series Amplifiers.)
COMMANDLIST, COMMUNICATION EXAMPLES and PARAMETER TABLES are
available at the end of each section of this document.
2. SERIAL PORT SETTING
•
9,600/19,200/38,400/57,600 bps, 8 bits, non-parity, stop bit: 1, non flow control
•
Connector: D-sub 9 pins, straight cable
•
Signal line: No.2=TX, No.3=RX, No.5=Ground