VULKAN GRD85F ML-126741 User Manual
Page 15
Advertising
– 15 –
LIGHTING INSTRUCTIONS FOR MANUAL PILOT IGNITION (Fig. 6)
CAUTION:
Before turning the burners on, the fry tank must be filled with liquid or melted
shortening.
Fig. 6
1. Turn thermostat knob (located behind the door panel) to OFF.
2. Push gas valve extension arm in and turn arm to OFF. Wait 5 minutes for unburned gas to vent.
3. Push gas valve extension arm in and turn to PILOT.
4. While still depressing the arm, light the pilot with a lit taper. Continue with steps 2 through 4 until
the pilot remains lit when the extension arm is released.
5. Push in and turn gas valve extension arm to ON.
6. Repeat steps 1 through 5 if gas supply is interrupted.
Advertising