Monitor input level settings -12, Control module jumper -12 – Western Telematic AFS-16-1 User Manual

Page 79

Advertising
background image

7-12

Alarm Configuration

7.6.1. Monitor Input Level Settings
When the Monitor/Alarm Input feature is properly configured, the AFS-16 can trigger an
alarm and/or perform A/B switching operations when the signal at Pin 4 (Monitor Input)
on the Control Module AUX connector goes high or low. In set up this feature, you must
first use the Control Card Jumper to select the non-active (non-alarm) state, and then
use the Monitor/Alarm Input configuration menu to select the active/alarm state (the
signal level that will trigger an alarm) as described in the Sections that follow.

Notes:

• The Monitor Input signal (Pin 4) is always measured relative to the signal at

the common ground (Pin 5).

• A "Low" signal should be between Zero (0) Volts and -48 Volts and a "High"

signal should be between +5 Volts and +48 Volts.

1

0

High

Low

Figure 7.2: Control Module Jumper

1

0

Control Card

Jumper

Back Edge of

Control Card

AUX Connector

Pin Out
Pin

Signal

5

Ground

4

Monitor Input

Figure 7.3: Control Module AUX Connector - Monitor Input and Ground