weber 178722 User Manual
weber Thermometers

INSTALLING AND REPLACING BATTERIES
The unit uses 1 LR-44 size battery which is included in the package.
Follow these steps to install or replace battery:
1. Use a screw driver to open the battery cover. (Follow the direction of
the arrow.)
2. Insert a new battery (make sure positive (+) is facing you).
3. Replace the battery cover.
NOTE Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specifications and warnings you should know about. Do not use a dishwasher to clean the
probe or immerse in water or liquid. Clean the probe with water and a mild detergent. Wipe the cabinet with a damp cloth.
FEATURES
Easy operation:
Displays the temperature reading automatically.
Error-free Reading: Digital display system ensures clear, error-free
reading at a glance.
Wide Range:
Measuring range from -50°C to 260°C
(-58°F to 500°F)
User Friendly:
User selectable normal or fast sampling cycle.
Plastic sleeve for sensor probe protection.
TEMPERATURE DISPLAY
AUTO - OFF
STAINLESS STEEL PROBE
PLASTIC SLEEVE
METAL CLIP
BATTERY COVER
1.5"–2"
EFFECTIVE
MEASURING AREA
ON/FAST
MAX/MIN
DISPLAY MODES
The thermometer has three different display modes:
TEMPERATURE MEASUREMENT
1. Pull out the Pocket Thermometer from the plastic sleeve.
2. Pierce the sensor probe into meat or place the sensor probe into water.
Press and hold the [ON/FAST] button for a faster sensing rate, the
measuring temperature will show on the display in a second. The
temperature sensing rate will operate at its normal speed if you do not
press the [ON/FAST] button.
Caution: The effective measuring area is 1.5"–2" from the tip.
Do not expose the main unit out of the operating temperature.
Caution: Do not leave the thermometer in the food on the grill.
USING THE MAXIMUM AND MINIMUM
TEMPERATURE MEMORY
The Pocket Thermometer will automatically record the maximum and minimum
measurements.
You can recall those readings by doing the following:
RESETTING THE MAXIMUM OR MINIMUM
TEMPERATURE MEMORIES
The Pocket Thermometer will automatically record the maximum and minimum
measurements.
You can reset those readings by doing the following:
SPECIFICATIONS
Operation temperature
: 0°C - 50°C (32°F - 122°F)
Temperature measuring range (probe) : -50°C to 260°C
(-58°F - 500°F)
Temperature display resolution
: Min 0.1°C to Max 0.5°C
(Min 0.2°F to Max 1°F)
Temperature sampling cycle
(Normal) : 10 seconds
(Fast) : 2 seconds
Power Source
: One (1) LR-44 battery
Battery life
: Approximate 6 Months
Metal probe size
: Diameter 2.8 mm ∞ 110 mm
Weight
: 30g (with plastic sleeve)
USING THE AUTO POWER OFF AND POWER OFF FUNCTIONS
Press the [AUTO-OFF] button. This enables “AUTO” to display, indicating
the thermometer will turn off automatically. If you do not press any key for
6 to 7 minutes, the thermometer will turn off automatically.
If you press the [AUTO-OFF] button once again, the thermometer will turn
off immediately.
Digital Pocket thermometer With
StainleSS Steel Probe
178722 8/07
WARRANTY
Weber-Stephen Products Co., (Weber
®
) hereby warrants to the ORIGINAL
PURCHASER of this Digital Pocket Thermometer, that it will be free
from defects in material and workmanship from the date of purchase as
follows: 2 year(s) when assembled, and operated in accordance with the
printed instructions accompanying it.
Weber may require reasonable proof of your date of purchase.
THEREFORE, YOU SHOULD RETAIN YOUR SALES RECEIPT
OR INVOICE.
This Limited Warranty shall be limited to the repair or replacement of
parts that prove defective under normal use and service and which on
examination shall indicate, to Weber’s satisfaction, that they are defective.
If Weber confirms the defect and approves the claim, Weber will elect to
repair or replace such parts without charge. If you are required to return
defective parts, transportation charges must be prepaid. Weber will return
parts to the purchaser, freight or postage prepaid.
This Limited Warranty does not cover any failures or operating difficulties
due to accident, abuse, misuse, alteration, misapplication, vandalism,
improper installation or improper maintenance or service, or failure to
perform normal and routine maintenance. Deterioration or damage due
to severe weather conditions such as hail, hurricanes, earthquakes or
tornadoes, discolouration due to exposure to chemicals either directly or
in the atmosphere, is not covered by this Limited Warranty. Weber shall not
be liable under this or any implied warranty for incidental or consequential
damages. This warranty gives you specific legal rights, and you may also
have other rights, which vary from state to state.
Weber Customer Service (US only) 1-800-446-1071.
DISPLAY MODE
FUNCTION
DISPLAY
Normal
Shows the current measuring
temperature.
22.3
Maximum Temperature
Memory
Shows the maximum temperature
recorded since last memory reset.
s 28.8
Minimum Temperature
Memory
Shows the minimum temperature
recorded since last memory reset.
t 18.8
Auto Power OFF
The thermometer will
automatically turn off, if you do not
press any key for 6 to 7 minutes.
AUTO 22.3
FUNCTION
CURRENT
DISPLAY
ACTION
NEXT
DISPLAY
Recall the
Maximum
temperature
22.3
Press [MAX/MIN] once
s
28.8
Recall the
Minimum
temperature
s
28.8
Press [MAX/MIN] once
again
t
18.8
Return to current
temperature
t
18.8
Press [MAX/MIN] once
again
22.3
FUNCTION
CURRENT
DISPLAY
ACTION
NEXT
DISPLAY
Reset the
Maximum
temperature
memory
s
28.8
(With the
Maximum
temperature
display)
Press and hold
[ON/FAST] button for 1
second.
s
22.3
(The current
temperature
will become
the maximum
memory)
Reset the
Minimum
temperature
memory
t
18.8
(With the
Minimum
temperature
display)
Press and hold
[ON/FAST] button for 1
second.
t
22.3
(The current
temperature
will become
the minimum
memory)
Return to current
temperature
t
22.3
Press [MAX/MIN] once
22.3
NOTE: You may like to clear the memory occasionally, so you can record
the Maximum / Minimum for a specified period.
Resetting a memory will result in the current temperature being
displayed in the Maximum or Minimum memory display.