White Rodgers 1F97-1277 User Manual
Caution, Applications, Specifications
Big Blue Single Stage Thermostat with
Automatic Heat/Cool Changeover Option
Single Stage Installation and Operating
Instructions for Model:
APPLICATIONS
1F97-1277 Touchscreen Thermostat
SPECIFICATIONS
Electrical Rating:
Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . . 20 to 30 VAC
Terminal Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 .5A per terminal, 2 .5A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 to 99°F (7 to 37°C)
Differential (Single Stage) . . . . . . . . . . . . . . . . . . . . Heat 0 .6°F; Cool 1 .2°F
Differential (Multi-Stage) . . . . . . . . . . . . . . . . . . . . . Heat 0 .6°F; Cool 1 .2°F
Differential (Heat Pump) . . . . . . . . . . . . . . . . . . . . . Heat 1 .2°F; Cool 1 .5°F
Operating Ambient . . . . . . . . . . . . . . . . . . . . . . . . . . 32°F to +105°F (0 to +41°C)
Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . . 90% non-condensing max .
Shipping Temperature Range . . . . . . . . . . . . . . . . . -4 to +150°F (-20 to +65°C)
Dimensions Thermostat . . . . . . . . . . . . . . . . . . . . . . 4-9/16"H x 5-13/16"W x 1-3/16"D
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
Model
Programming Choices
1F97-1277
Non-Programmable 5/1/1 Day
7 Day
THERMOSTAT APPLICATION GUIDE
Description
Heat Pump (No Aux . or Emergency Heat)
No
Heat Pump (with Aux . or Emergency Heat)
No
Systems with up to 3 Stages Heat, 2 Stages Cool
No
Heat Only Systems
Yes
Millivolt Heat Only Systems – Floor or Wall Furnaces
Yes
Cool Only Systems
Yes
Gas or Oil Heat
Yes
Electric Furnace
Yes
Hydronic (Hot Water) Zone Heat – 2 Wires
Yes
Hydronic (Hot Water) Zone Heat – 3 Wires
Yes
Wired Remote Temperature Sensor (Indoor/Outdoor)
Yes
Dual Fuel Feature (Heat Pump Mode)
No
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
Index
Page
Installation
2
Wiring Connections
2
Thermostat Quick Reference
4
Installer Configuration Menu
5
Operating Your Thermostat
8
Programming
9
Troubleshooting
12
ATTENTION: MERCURY NOTICE
This product does not contain mercury . However, this
product may replace a product that contains mercury .
Mercury and products containing mercury must not be
discarded in household trash . Do not touch any spilled
mercury . Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container . For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container . Refer to
www.thermostat-recycle.org for
location to send the product containing mercury .
PART NO. 37-6814C
Replaces 37-6814B
1150
www.white-rodgers.com
www.emersonclimate.com