Operation – Western Telematic 12651 User Manual

Page 11

Advertising
background image

5.

Operation

The device connected to the Control Port must send ASCII

characters at the same data rate as the RPB+. The unit accepts 8

bits no parity, or 7 bits even or odd parity, but will always

answer back at 8 bits, no parity.

Access the RPB+ Command Mode as described in Section 4,

Step 1. When the "RPB+>" prompt appears, the user may invoke

the following commands.

Notes:

·

Commands are not case sensitive.

·

Wait for the "RPB+>" prompt to appear before

entering commands. The prompt will not re-appear

until the previous command is complete.

·

If an invalid command or parameter is entered, the

RPB+ will respond with the "?" message.

1. Switch Plug(s) On: To power-on one or all of the five

switched plugs, type /n ON [Enter]. Where "n" is a plug

number from 1 to 5 and an asterisk (*) indicates the

command should be applied to all plugs.

2. Switch Plug(s) Off: To power-off one or all of the five

switched plugs, type /n OFF [Enter]. Where "n" is a

plug number from 1 to 5 and an asterisk (*) indicates the

command should be applied to all plugs. Note that "OFF"

can also be entered as "OF".

3. Boot Plug(s): To initiate a Boot cycle at one or all of the

switched plugs, type /n BOOT [Enter]. Where "n" is a

plug number from 1 to 5 and an asterisk (*) indicates the

command should be applied to all plugs. Note that

"BOOT" can also be entered as "B". The RPB+ will display

a series of periods (dots) while the Boot cycle is in

progress.

4. Status: To display the Status Screen, type /S [Enter].
5. Enter Parameters: To define parameters, such as the

Location I.D., Power-Up Default, and Plug Labels, type

/P [Enter] and refer to Section 4, Step 4.

Page 9

Operation