5-30

Command

Sets

COMMAND BIT DEC HEX

FUNCTION

AND

DESCRIPTION

REF.

32 20 ATX4

X4

40

28

ATX5, error control result code is enabled (default).

X5

48

30

ATX6, error control result code is enabled.

X6

56

38

ATX7, error control result code is enabled.

X7

6

0

0

Displays the result code in numeric format (see
S35.7).

V0

64

40

Displays the result code in verbose format (default).

V1

7 0 0 The

modem

returns

the

result code (default).

Q0

128

80

The modem does not return the result code (see also
S40.1).

Q1

bit dec hex Bit-mapped

register.

S24=

6-4 16-

112

10-70

Speaker volume control, increments of 16 in decimal
value.

L0-3

S25= 0

to

255

0-FF

Specify the time delay that the DTR signal needs to be
OFF before it is recognized, in 10 ms units. If S25=0,
the delay time is set to 4 ms.

+000

dec hex RTS/CTS

delay.

+000

S26=

0

to

255

0-FF

Set the delay, in 10 millisecond units between the RTS
and the modem's CTS response in synchronous mode
(see '&Rn' command).

&Rn

bit dec hex Bit-mapped

register.

+156

0-2

Modem

error

control.

0 0 No

error

control.

&K0

1

1

MNP4 + MNP3 (see also S41.0).

&K1

2

2

MNP4 + MNP5 (see also S38.5, S41.0).

&K2

3 3 V.42+MNP4

&K3

4

4

V.42 + V.42bis (compatible with &K2) (default).

&K4*

3-5

0 0 Flow

control

disabled

24

18

Hardware (RTS/CTS) flow control (default)

S27=

32

20

Software (RTS/CTS) flow control

Advertising