InStallatIOn

Specification

connection example for single circuit operation

2

L3

L2

L1

N

1

4

3

26

�02

�7

9�

002

1

connection example for single circuit operation with power-

oFF contact

2

L3

L2

L1

N

1

4

3

1

26

�0

2�

79

�0

05

1

1 Power-OFF contact, installed by the heating contractor

14.3 specification

FCR 18/60 FCR 18/90 FCR 28/120 FCR 28/120 FCR 28/180 FCR 28/180 FCR 28/270 FCR 28/360

000691

000692

071332

000694

071333

000695

000696

001502

Electrical data
Connected load ~ 400 V

kW

6

9

6/12

12

9/18

18

27

36

Rated voltage

V

400

400

400

400

400

400

400

400

Phases

3/PE

3/PE

3/N/PE

3/PE

3/N/PE

3/PE

3/PE

3/PE

Frequency

Hz

50/60

50

50

50

50

50

50

50/60

Single circuit operating mode

X

X

X

X

X

X

Dual circuit operating mode

X

X

Application limits
Temperature setting range

°C

35-85

35-85

35-85

35-85

35-85

35-85

35-85

35-85

Max. permissible pressure

MPa

1.0

1.0

1.0

1.0

1.0

1.0

1.0

1.0

Minimum cylinder diameter

mm

450

450

550

450

550

450

450

550

Minimum cylinder volume

l

200

200

300

200

300

200

200

300

Versions
IP rating

IP24

IP24

IP24

IP24

IP24

IP24

IP24

IP24

Dimensions
External flange diameter

mm

180

180

280

280

280

280

280

280

Immersion depth

mm

325

325

450

325

450

325

325

450

Torque

Nm

55

55

80

80

80

80

80

80

Weights
Weight

kg

13.5

15.5

13

13

13

13

13

17

Advertising