25-62-10

Page 71 of 90

JUL 31/12

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

C406-1 (453-5002), C406-1HM (453-5003)

SUBTASK 25-62-10-450-008

I.

Airframe Ground Connections

(1)

Connect the ground wires to the airframe in accordance with the aircraft manufacturer’s

written instructions or as described in AC 43.13-1, Chapter 11, § 15. See "Figure 21. Remote

Switch Harness Wiring Diagram”, on page 67.

SUBTASK 25-62-10-450-009

J.

Buzzer Connection

(1)

Connect the power wire to the buzzer positive (+) terminal.

(2)

Connect the ground wire to the buzzer negative (–) terminal.

SUBTASK 25-62-10-450-010

K. Remote Switch Final Installation

(1)

Insert the harness plug into the remote switch receptacle.

(2)

Install the remote switch assembly, referring to SUBTASK 25-62-10-450-002, on page 63.