Actron Elite AutoScanner® CP9185 User Manual

Page 32

Advertising
background image

Getting Started

2 – 14 • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

2

Chrysler Historic

Prior to 1996, most Chrysler vehicles used either the serial

communications interface (SCI) or LH DLC. Refer to Appendix B -

Data Link Connectors for DLC type and location. The SCI adapter

cable is included with the Scan Tool. The LH adapter cable (CP9130)

can be purchased from your dealer.

Use the cigarette lighter cable to provide 12V to the tool

when using the SCI adapter cable.

Serial Communications Interface SCI

The SCI (serial communications interface) DLC

is a 6-pin connector located in the engine

compartment. The adapter cable to be used on

these vehicles is supplied with the tool. This

cable is labeled CHRY on the 15-pin DB style

connector and SCI on the vehicle end.

LH

This DLC is used on LH platform vehicles. The

LH style DLC is a small, blue, rectangular 6-pin

connector located in the passenger

compartment below the dashboard to the right of

the steering column.
The LH Adapter Cable (CP9130) is optional and

must be purchased separately.

IMPORTANT

SCI

LH (P/N CP9130)

Advertising