Demonstration mill pwr, Operation manual – ACU-RITE MILLPWR Old Style User Manual
Page 76

DEMONSTRATION
MILLPWR
Page 4-22
Operation Manual
Tool Changes
Whenever
MILLPWR
encounters a
SET
TOOL
step, it shows you the DRO and
tells you which tool to load.
•
Use the
MOVE
TABLE
function to clear
the workpiece.
•
Load the required tool.
•
Using the move table function, position the tool over a surface
of known depth.
•
Press the
DATUM
softkey.
•
Touch the end of the tool to the
surface, key the known depth into the
Z axis.
Press the
USE
key.
•
Raise the tool and press
GO
to resume the program.
•
Follow the instructions on the
MILLPWR
screen.
Clearing the Program
Select
PROGRAM FUNCTIONS
again.
PROGRAM
FUNCTIONS
Select the softkey marked
CLEAR
to clear the program
from the screen.
You may wish to
consider using a
POS step before
a tool step to
allow room for
changing the
tool.
MOVE
TABLE
Load tool.
If the surface is
at 0, use the Z =
0 key.
Use move table function to
position the tool.
MOVE
TABLE
Touch end of
tool to
surface.
Key in depth
of Z axis.
USE
Raise tool.
GO
CLEAR
DATUM