Power-Sonic PHR-12350 User Manual
12 volt 95 ah, 370 w/cell, Hr. rate
HT
H
W
L
016
3
M6
Physical Dimensions: in (mm)
Features
• Superb high-rate discharge characteristics that ensure reliable
performance in UPS applications for up to 10 years. UL recognized
• Flame retardant ABS case and cover to UL 94 V-O for superior
performance
• VRLA Absorbent Glass Mat (AGM) Technology guarantees safe
operation without maintenance and “non-restricted article” status for
transportation. Approved for transport by air. D.O.T., I.A.T.A. and
F.A.A. certified.
• Precision plate pasting for higher consistency with 100% load
testing to ensure uniform capacity
• Patented dual-paste process for enhanced active material bonding,
and computer guided volumetric electrolyte control for precision
filling
• Lead-calcium alloy grids and the use of high purity lead account for
superior shelf-life characteristics
Performance Specifications
Nominal Voltage ............................................... 12 volts (6 cells)
Nominal Power (15 min.) .....................................370 W/Cell
Rated Capacity
20-hr. (4.75A to 10.80 volts) ...................................... 95.0 AH
10-hr. (9.25A to 10.50 volts) ...................................... 92.5 AH
8-hr. (11.20A to 10.50 volts) .................................... 89.6 AH
Approximate Weight .................................. 60.4 lbs. (27.4 kg)
Internal Resistance (approx.) ................................ 4.0 milliohms
Max Discharge Current (5 Sec.) ......................... 1425 amperes
Charging Voltage @ 77°F (20° C)
Standby Use ............. 2.275 ± 0.025 V/Cell, (-3.3mV/°C/Cell)
Cycle Use .......................... 2.45±0.05 V/Cell, (-5 mV /°C/Cell)
Maximum Charging Current ....................................... 28.5 A
Case .................................. Flame Retardant ABS Plastic (UL 94 V-O)
PHR-12350
L: 12.00(305) W: 6.61 (168) H: 8.15 (207) HT: 8.27 (210)
12 Volt 95 AH
@ 20-hr. rate
370 W/Cell
@ 15-min. rate
Constant Current Discharge (Amperes) at 25ºC
Constant Power Discharge (Watts/Cell) at 25ºC (Blue)
www.power-sonic.com
To ensure safe and efficient operation always refer to the latest edition of our Technical Manual, as published on our website.
All data subject to change without notice.
Tolerances are +/- 0.04 in. (+/- 1mm) and +/- 0.08 in. (+/- 2mm) for height dimensions.
PHR-12350
5 min
10 min
15 min
20 min
30 min
45 min
1h
2h
3h
4h
5h
6h
8h
10h
20h
1.85V
209.8
171.1
145.5
123.1
95.0
69.9
56.5
33.7
24.4
19.1
15.8
13.6
10.7
8.84
4.63
1.80V
234.8
190.7
158.5
133.1
100.7
73.4
59.2
65.0
25.1
19.8
16.3
14.0
10.9
9.07
4.75
1.75V
262.2
209.2
171.4
142.2
105.8
76.7
61.6
35.8
25.7
20.1
16.7
14.3
11.2
9.25
4.86
1.70V
290.7
226.9
182.4
151.3
111.2
80.1
63.5
36.6
26.2
20.6
17.1
14.6
11.4
9.43
4.94
1.67V
321.5
242.8
195.3
159.6
116.5
82.8
65.3
37.3
26.7
21.0
17.3
14.9
11.6
9.59
5.03
1.60V
348.8
258.8
205.6
166.7
120.4
85.8
67.5
38.3
27.2
21.4
17.7
15.2
11.9
9.76
5.16
1.85V
408.1
334.7
286.3
243.4
188.8
139.6
113.2
67.8
49.2
38.8
32.2
27.7
21.8
18.2
9.58
1.80V
452.1
369.2
308.6
260.6
198.3
145.4
117.7
69.9
50.4
39.8
33.1
28.3
22.3
18.6
9.76
1.75V
499.6
401.3
330.8
276.0
206.7
150.7
121.6
71.1
51.3
40.3
33.5
28.9
22.7
18.8
9.93
1.70V
547.6
430.4
348.0
290.7
214.9
155.8
124.3
72.1
52.0
41.1
34.1
29.2
23.0
19.1
10.0
1.67V
600.7
457.2
370.3
304.6
223.9
160.4
127.2
73.1
52.7
41.6
34.4
29.6
23.3
19.3
10.2
1.60V
644.5
482.0
385.7
315.2
229.1
164.4
130.2
74.5
53.2
42.0
34.9
29.9
23.6
19.4
10.3