2 dimensions, Plastic housing – VEGA VEGABAR 52 4 … 20 mA User Manual
Page 50

50
10 Supplement
VEGABAR 52 • 4 … 20 mA
36716-EN-130321
Functional safety according to IEC 61508-4
Ʋ Single channel architecture (1oo1D) up to SIL2
Ʋ double channel diversitary redundant
architecture (1oo2D)
up to SIL3
You can find detailed information in the supplied Safety Manual of the instrument series or under
"www.vega.com", "Downloads", "Approvals".
Approvals
Instruments with approvals can have different technical data depending on the version.
For that reason the associated approval documents of these instruments have to be carefully
noted. They are part of the delivery or can be downloaded under www.vega.com via "VEGA Tools"
and "serial number search" as well as via "Downloads" and "Approvals".
10.2 Dimensions
The following dimensional drawings represent only an extract of the possible versions. Detailed
dimensional drawings can be downloaded on www.vega.com under "Downloads" and "Drawings".
The double chamber housings are only available for Ex-d version with instruments with 4 … 20 mA
signal output.
Plastic housing
~ 69 mm
(2.72")
ø 79 mm
(3.03")
112 mm (4.41"
)
M20x1,5/
½ NPT
~ 84 mm (3.31")
M16x1,5
112 mm (4.41"
)
M20x1,5/
½ NPT
1
2
ø 79 mm
(3.31")
Fig. 21: Housing versions in protection IP 66/IP 68 (0.2 bar) - with integrated display and adjustment module the
housing is 9 mm/0.35 in higher
1 Single chamber version
2 Double chamber version