4 Mounting
MINITRAC 31 • Foundation Fieldbus
41782-EN-131119
L
L
L
1
4
a
b
2
3
Fig. 5: Installation possibilities - Density measurement or concentration meas-
urement
1a Radial raditiona - vertical mounting
1b Axial radiation - Horizontal mounting or when the lead cover is used as
protection against ambient radiation
2 Inclined radiation for extention of the radiated length (L)
3 Extension of the radiated length (L) by adding a tube angle piece as meas-
uring distance
4 Integrated lead cover as protection against ambient radiation - the instru-
ment is hence shielded laterally
With density measurement, the radiation difference with differing
density is very low. Especially with small tube diameters, the change
is negligible.
Therefore it is important to shield from interfering X-ray radiation. To
protect the instrument against X-ray radiation, it can be be equipped