Alarm SMS content when input 2 tension is high
Password
Command TIN2A:xxxxxxxx

xxxxxxxx = message (max. 100 characters, all capitals)

Example

TIN2A: TENSION ON INPUT 2

Result

When tension is detected on input 1, an SMS is sent out with text “TENSION

ON INPUT 2”. Default: ALARM! INPUT 2 HIGH

Note:

a semi colon (;) is not allowed inside the message

Alarm SMS content when input 2 tension is low
Password
Command TIN2B:xxxxxxxx

xxxxxxxx = message (max. 100 characters, all capitals)

Example

TIN2B: NO TENSION ON INPUT 2

Result

When no tension is detected on input 1, an SMS is sent out with text “NO

TENSION ON INPUT 2”. Default: ALARM! INPUT 2 LOW

Note:

a semi colon (;) is not allowed inside the message

Activate a relay output
Password
Command OUTx:ON

x = 1 (output 1) or 2 (output 2)

Example OUT1:ON
Result

Activate output relay 1

Deactivate a relay output
Password
Command OUTx:OFF

x = 1 (output 1) or 2 (output 2)

Example OUT2:OFF
Result

Deactivate output relay 2

Invert the condition of a relay for a certain time
Password
Command OUTx:ss

x = 1 (output 1) or 2 (output 2)

ss = time in seconds (00~59)

Example OUT1:10
Result

Deactivate (when already active) or activate (when deactivated) output relay
1 for the next 10 seconds.

Request condition of outputs
Password
Command STA?
Example STA?
Result

Get an overview of the condition of the output relays.

Store and restore relay status after power cut
Password
Command RIPx

x = 0 (disabled) or 1 (enabled)

Example RIP1
Result

Relay statuses are automatically stored when a power outage occurs and

restored when power is restored. Default: 1 (enabled)