Velleman HAMGSM133 User Manual
Page 12
HAMGSM133
V. 02 – 15/05/2012
12
©Velleman nv
Alarm SMS content when input 2 tension is high
Password
Command TIN2A:xxxxxxxx
xxxxxxxx = message (max. 100 characters, all capitals)
Example
TIN2A: TENSION ON INPUT 2
Result
When tension is detected on input 1, an SMS is sent out with text “TENSION
ON INPUT 2”. Default: ALARM! INPUT 2 HIGH
Note:
a semi colon (;) is not allowed inside the message
Alarm SMS content when input 2 tension is low
Password
Command TIN2B:xxxxxxxx
xxxxxxxx = message (max. 100 characters, all capitals)
Example
TIN2B: NO TENSION ON INPUT 2
Result
When no tension is detected on input 1, an SMS is sent out with text “NO
TENSION ON INPUT 2”. Default: ALARM! INPUT 2 LOW
Note:
a semi colon (;) is not allowed inside the message
Activate a relay output
Password
Command OUTx:ON
x = 1 (output 1) or 2 (output 2)
Example OUT1:ON
Result
Activate output relay 1
Deactivate a relay output
Password
Command OUTx:OFF
x = 1 (output 1) or 2 (output 2)
Example OUT2:OFF
Result
Deactivate output relay 2
Invert the condition of a relay for a certain time
Password
Command OUTx:ss
x = 1 (output 1) or 2 (output 2)
ss = time in seconds (00~59)
Example OUT1:10
Result
Deactivate (when already active) or activate (when deactivated) output relay
1 for the next 10 seconds.
Request condition of outputs
Password
Command STA?
Example STA?
Result
Get an overview of the condition of the output relays.
Store and restore relay status after power cut
Password
Command RIPx
x = 0 (disabled) or 1 (enabled)
Example RIP1
Result
Relay statuses are automatically stored when a power outage occurs and
restored when power is restored. Default: 1 (enabled)