3. Bin Assembly

16

PNEG-1400 WCL Commercial 4" Corrugation Externally Stiffened Grain Bin

Bolting Requirements - 2 Stiffeners per Sidewall Sheet

• Use 3/8" x 1-1/2" (S-5060) bin bolts at splice locations to attach the stiffener/splice plate to the sidewall.

• Use 3/8" x 1-1/2" (S-5060) bin bolts on laminated stiffeners to attach stiffeners to the sidewall sheet.

• Refer to

Stiffener Assembly Details on Page 35

and the

Caulking Detail on Page 19

for stiffener

assembly hardware usage and caulking details. Refer to

Hardware

identification section

on Page 18

for aid in hardware identification.

Figure 3C As Viewed from Outside

Sidewall Gauge

Horizontal Seam

Vertical Seam

Stiffener to Sidewall

Overlap Seam

20-15

5/16" x 3/4" (S-275)

[8]

5/16" x 3/4" (S-275)

[42]

3/8" x 1" (S-455)

[22]

5/16" x 3/4" (S-275)

[2]

14-12

3/8" x 1" (S-455)

[20]

3/8" x 1" (S-455)

[42]

3/8" x 1" (S-455)

[22]

3/8" x 1" (S-455)

[2]

11-9

7/16" x 1" (S-9312)

[20]

7/16" x 1" (S-9312)

[42]

3/8" x 1" (S-455)

[22]

7/16" x 1-1/2" (S-3885)

[2]

8

7/16" x 1" (S-9312)

[20]

1/2" x 1-1/2" (S-9307)

[42]

3/8" x 1-1/2" (S-5060)

[22]

7/16" x 1-1/2" (S-3885)

[2]

13L-6L

(Laminated)

7/16" x 1-1/2" (S-3885)

[20]

1/2" x 1-1/2" (S-9307)

[63]

3/8” x 1-1/2" (S-5060)

[22]

7/16" x 1-1/2" (S-3885)

[4]