B&B Electronics USR604 - Manual User Manual

Page 10

Advertising
background image

Section 3 - Quick Start Guide

Page 10 of 45

Document Number: USR60x-0812m

www.bb-elec.com/

www.bb-europe.com/

USR604: Connect 10 to 48VDC to terminal block and/or barrel
jack

5. Check

LED Indicators

(on page 23)

Power indicated by green Pwr LED

Tx and Rx LEDs will indicate when data present

6.

Set up the COM Port operating modes

(see "

Setting COM Port

Operating Modes

" on page 21)

Configure the DIP switches for each port to select one of the
following:

RS-232 (Both DIP switches Off)

RS-422 (Both DIP switches On)

RS-485 4-wire (SW1 Off, SW2 On)

RS-485 2-wire (SW1 On, SW2 Off)

7.

Connect the serial ports

(see "

Connecting to the Serial Ports

" on

page 20):

Connect from the DB-9M connectors on the converter to your
devices or network:

To connect to an RS-232 DTE device, use a null modem
(crossover) cable

To connect to an RS-485 two-wire network, refer to

RS-485

Two-Wire Connections

(on page 43)

To connector an RS-422 device, or an RS-485 four-wire
network, refer to

RS-422 and RS-485 Four-Wire Connections

(on page 44)

8.

Configure the serial ports

(see "

Advanced Settings in Device

Manager

" on page 27)

On the PC screen, open the Control Panel.

Click System to open the Device Manager

Under Ports, double-click the port to be configured.

On the Serial Port Properties window, set the required
communications parameters of system with which you are
communicating.

If necessary, click Advanced and set up the Advanced Properties
(refer to manual for information)

Advertising