GE P&W Spiral Wound Membranes - AK LE Series User Manual

Ak le seri, High flow low energy brackish water ro elements, Fact sheet

Advertising
background image

Find a contact near you by visiting www.ge.com/water and clicking on “Contact Us”.

* Trademark of General Electric Company; may be registered in one or more countries.

©2011, General Electric Company. All rights reserved.

FSpwAKLESeries_EN Oct-11




Fact Sheet

AK LE Seri

e

s

High Flow Low Energy Brackish Water RO Elements

The A-Series family of proprietary thin-film reverse
osmosis membrane is characterized by high flux
and high sodium chloride rejection. AK LE brackish
water elements are selected when high rejection,
high flow and ultra-low operating pressures are
desired.
The AK LE element is a low energy high flow ele-
ment for beverage, light commercial, residential
and general industrial applications. AK LE Series
elements feature a Fiberglass outer wrap.

Table 1: Element Specification

1

Average salt rejection after 24 hours operation. Individual flow rate

may vary +25%/-15%.

2

Testing conditions: 500ppm NaCl solution at 115psi (793kPa) operat-

ing pressure, 77°F (25°C), pH7 and 15% recovery.




Table 2: Operating and CIP parameters

3

SDI is measured on a non-linear scale using a 0.45 micron filter paper.

Additionally, finer colloids, particulates and microorganisms that pass
through the filter paper and not measured in the SDI test, will potential-
ly foul the RO element. For performance consistency and project war-
ranty, please use Winflows projection software and consult your Filters
with Membranes representative.


Figure 1a: Element Dimensions Diagram – Male







Figure 1b: Element Dimensions Diagram – Female




Membrane

Thin-film membrane (TFM*)

Model

Average

permeate flow

gpd (m3/day)

1,2

Average

NaCl

rejection

1,2

Minimum

NaCl

rejection

1,2

AK-90 LE

2800 (10.6)

99.3%

99.0%

AK-400 LE

12300 (46.6)

99.3%

99.0%

AK-440 LE

13500 (51.1)

99.3%

99.0%

Model

Active area

ft

2

(m

2

)

Outer wrap

Part

number

AK-90 LE

90 (8.4)

Fiberglass

3056683

AK-400 LE

400 (37.2)

Fiberglass

3056684

AK-440 LE

440 (40.9)

Fiberglass

3056685

Typical Operating Pressure

110 psi (758 kPa)

Typical Operating Flux

10-20GFD (15-35LMH)

Maximum Operating Pressure 400 psi (2,758 kPa)

Maximum Temperature

Continuous operation: 122°F (50°C)
Clean-In-Place (CIP): 122°F (50°C)

pH range

Optimum rejection: 7.0-7.5,
Continuous operation 4.0-11.0,
Clean-In-Place (CIP): 2.0-11.5

Maximum Pressure Drop

Over an element: 12 psi (83 kPa)
Per housing: 50 psi (345 kPa)

Chlorine Tolerance

1,000+ ppm-hours,
dechlorination recommended

Feedwater

3

NTU < 1
SDI < 5

Advertising