PROGRAMMING:


All operating parameters (vend price, temperatures, cool-down times, etc.) are adjustable. There
are also several displays of information available from the controller (money audits, hours run,
and dryer temperature.)

The dryer is shipped ready for operation with the following pre-programmed data:

Temperature- HOT (or HIGH):

175°F/ 78°C

Temperature- MEDIUM:

150°F/ 63°C

Temperature- WARM (or LOW):

125°F/ 48°C

Vend Price:

25¢

Time for Left Coin Slot:

3:20 (does not apply to single coin models)

Time for Right Coin Slot:

8:00 (8 minutes for 25¢)

Time for Free Vend:

8:00

Cool-down Time HOT (or HIGH):

2:00

Cool-down Time MEDIUM:

2:00

Cool-down Time WARM (or LOW):

2:00

Temperature Scale:

°F

Decimal Point Display:

ON

Seconds on Display:

OFF


All of the above data can easily be changed by the owner. The changes are made by the 4 keys
or buttons on the front of the control panel.

CHANGING PROGRAM DATA


Put dryer in PROGRAM mode (see “Programming Instructions”). The dryer remains in the
PROGRAM mode until one of these actions occur:

·

The switch is actuated again.

·

The seventeenth step is completed, and the START switch is pushed following the
seventeenth step.

·

Programming is stopped for about a minute.

·

The loading door is closed.

·

Observe the displayed value in each step. If no change is required, press START to advance to
the next program step. If a change is required the values are made larger by the HOT (or HIGH)
button, smaller by the MED button. The hour meter and money audit can be reset to zero if
WARM (or LOW) is pressed.

Note: After any reset or program change, it is necessary to advance to the next step by pressing
START to enter the revision. OTHERWISE THE VALUE WILL REMAIN AS IT WAS
BEFORE THE ALTERATION.