ELECTRICAL

╔════════════════════════════════════════════════════════════════════╗

WARNING
SHUT OFF POWER AND WATER BEFORE OPENING ANY SERVICE PANELS.

╚════════════════════════════════════════════════════════════════════╝

Dexter T900/T950 washing machines are intended to be permanently installed

appliances. The machine should be connected to an individual branch circuit not

shared by lighting or other equipment. The connection should be sheathed in

liquid-tight flexible conduit, or equivalent, with conductors of the proper size

and insulation. No power cord is provided. Such connections should be made by

a qualified electrician, in accordance with the wiring diagram. (Suggest

minimum wire size of 12 ga.)

FUSING REQUIREMENTS

15 Amp Time Delay (Dual Element) Fuse(s) (or equivalent circuit breaker).

TO MAKE ELECTRICAL CONNECTIONS:

Remove screw and lift out cover located on upper left of machine (viewed from

back).

Figure 3 - Electrical Power Connections

If power is 208-240-3PH-60HZ

connect L1, L2, L3 and ground.

(If there is a high phase it

must be connected to L3.)

If power is 208-240-1PH-60HZ

connect L1, L2 and ground.

IMPORTANT


FOR SAFETY AND PROPER EQUIPMENT
OPERATION THE GROUND LUG MUST
BE CONNECTED TO A GOOD EXTERNAL
GROUND.