Ct **

Tumble Time

Two-digit amount of time in minutes.

t **

Water Temperature

HH for hot, CH for warm, CC for cold
and EE for no water.

L **

Water Level

Lo for low, Hl for high.

dF *

Type of Fill

d for delayed fill, t for timed fill.

1

S **

Spin Time

Two-digit amount of time in minutes.

IS *

Injection Source

Single digit code indicating injector signal(s).

2

1

A delayed fill will pause the time count until the selected level is reached. A timed fill will

only fill for a predetermined amount of time.

2

Codes for injections sources are defined at the end of the programming section. When the No

Water bath is selected, the electronic controller prohibits injection signals. The programmed
injection source value is ignored.


To exit the programming of a bath, press the “STOP” button once and use the “UP” and “DOWN”
keys select another bath. Press the “STOP” button again to select a different cycle to change. To
end programming, turn the key to “RUN” position






WASHER CYCLE PARAMETER RANGES

The range of each cycle parameter is shown below:

Cycle Time

0 to 15 minutes for Prewash, Wash, Rinse1, 2, 3 and 4
1 to 15 minutes for Final Rinse
For the bathes that can, if the time is set to zero, then the bath
will be eliminated from the cycle.

Water Temperature

HH – hot, CH – warm, CC – cold, EE – no water


Water Level

HI – high, LO – low


Delay Fill

The selections are “d” for delay the bath time until water level
is reached or “t” for decrement bath time during the fill.


Spin Time

0 to 10 minutes for Prewash, Wash, Rinse, 2, 3 and 4
1 to 10 minutes for Final Spin

Injection Source

0 to 6

Note: The Wash Cycle programming mode will automatically exit and return to

the Idle mode if no buttons are pushed for one minute.